CBR4-AFN-03
Superisys
RS485
Availability: | |
---|---|
Quantity: | |
Excellent transmission performance:
Adopts special design and shielding structure to reduce signal attenuation and interference, and achieve high-speed and stable data transmission.
Strong anti-interference ability:
has excellent electromagnetic shielding performance, effectively resists external electromagnetic interference, and ensures signal transmission quality.
High durability
Made of high-quality materials, wear-resistant and tensile-resistant, adaptable to complex environments.
Min. Order Quantity | 1PCS |
Price | Large quantity price negotiable |
Delivery Time | 3 work days |
Stock | In Stock |
Payment Terms | T/T, Western Union |
Supply Ability | 1000 per day |
Type | CBR4-AFN-03-G1 | CBR4-AFN-03 |
Picture | ![]() | ![]() ![]() |
Length | 3 Meters | 3 Meters |
Connector type | M12A female straight connector-loose wire | M12A female elbow M12A type male straight head |
Number of pins | 5 | 5 |
Cable diameter | 5.6mm | 5.6mm |
Core size | 2P*24AWG | 2P*24AWG |
Color | Black | black |
Cable material | PUR | PUR |
Cable shield | Yes | Yes |
Operating temperature | -25℃~80℃ | -25℃~80℃ |
Other options | CBR4-AFN-05 5m | CBR4-AFN-05-G1 5m |
CBR4-AFN-10 10m | CBR4-AFN-10-G1 10m | |
Bending times | / | 5 million times (G2: 10 million times G3: 15 million times G4: 20 million times) |
1. PLC control system
RS485 cable connects sensors, actuators and other equipment. Through the RS485 protocol, PLC can efficiently collect sensor data and send control instructions to the actuator to achieve precise control of the production process.
2. Remote monitoring system
In remote monitoring scenarios, RS485 cables can be used to connect monitoring equipment and control centers. RS485 cables can connect scattered equipment to the central monitoring system to achieve remote monitoring and data acquisition.
3. Data acquisition system
RS485 cables support multi-point communication and can connect multiple data acquisition terminals. In factory automation environments such as automobile manufacturing and metal processing, RS485 cables can be used to connect multiple sensors and centrally transmit production data to the data acquisition system for real-time monitoring and analysis.
4. Industrial robots and CNC machine tools
For medium-distance and medium-speed communication requirements, RS485 cables can meet the communication requirements between industrial robots and CNC machine tools. Through the RS485 interface, collaborative work and data interaction between devices can be achieved.
Excellent transmission performance:
Adopts special design and shielding structure to reduce signal attenuation and interference, and achieve high-speed and stable data transmission.
Strong anti-interference ability:
has excellent electromagnetic shielding performance, effectively resists external electromagnetic interference, and ensures signal transmission quality.
High durability
Made of high-quality materials, wear-resistant and tensile-resistant, adaptable to complex environments.
Min. Order Quantity | 1PCS |
Price | Large quantity price negotiable |
Delivery Time | 3 work days |
Stock | In Stock |
Payment Terms | T/T, Western Union |
Supply Ability | 1000 per day |
Type | CBR4-AFN-03-G1 | CBR4-AFN-03 |
Picture | ![]() | ![]() ![]() |
Length | 3 Meters | 3 Meters |
Connector type | M12A female straight connector-loose wire | M12A female elbow M12A type male straight head |
Number of pins | 5 | 5 |
Cable diameter | 5.6mm | 5.6mm |
Core size | 2P*24AWG | 2P*24AWG |
Color | Black | black |
Cable material | PUR | PUR |
Cable shield | Yes | Yes |
Operating temperature | -25℃~80℃ | -25℃~80℃ |
Other options | CBR4-AFN-05 5m | CBR4-AFN-05-G1 5m |
CBR4-AFN-10 10m | CBR4-AFN-10-G1 10m | |
Bending times | / | 5 million times (G2: 10 million times G3: 15 million times G4: 20 million times) |
1. PLC control system
RS485 cable connects sensors, actuators and other equipment. Through the RS485 protocol, PLC can efficiently collect sensor data and send control instructions to the actuator to achieve precise control of the production process.
2. Remote monitoring system
In remote monitoring scenarios, RS485 cables can be used to connect monitoring equipment and control centers. RS485 cables can connect scattered equipment to the central monitoring system to achieve remote monitoring and data acquisition.
3. Data acquisition system
RS485 cables support multi-point communication and can connect multiple data acquisition terminals. In factory automation environments such as automobile manufacturing and metal processing, RS485 cables can be used to connect multiple sensors and centrally transmit production data to the data acquisition system for real-time monitoring and analysis.
4. Industrial robots and CNC machine tools
For medium-distance and medium-speed communication requirements, RS485 cables can meet the communication requirements between industrial robots and CNC machine tools. Through the RS485 interface, collaborative work and data interaction between devices can be achieved.