You are here: Home » Products » Communication /IO LINK Module » IO-Link Master » EtherCAT IP67 8 Ports IO LINK Master Communication Module
 IP68 8 Ports IO LINK Master Communication Module
 IP68 8 Ports IO LINK Master Communication Module  IP68 8 Ports IO LINK Master Communication Module
 IP68 8 Ports IO LINK Master Communication Module  IP68 8 Ports IO LINK Master Communication Module

loading

EtherCAT IP67 8 Ports IO LINK Master Communication Module

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button
IO Link Master 8 Ports, 
EtherCAT protocol
IP67 Protection grade
  • IACM-IOLM8A-ECT-E

  • Superisys

Availability:
Quantity:


Product Features:

1.  Designed with IO-Link v1.1 specification

2. The master station supports three communication rates: COM1, 2, and 3.

3. Interface type Class-A or Class-B optional

4. Seamless connection with IO-Link protocol RFID reading and writing devices, sensors, valve islands, etc.

5. Meet CE, FCC, RoHS, certificate.

Introduction:

IACM-IOLM8A-ECT-E

IACM-IOLM8A-ECT-E coupler is a field-type IO-Link master module, EtherCAT bus protocol, 8-way IO-Link interface, 8-way ClassA/ClassB can be freely configured; maximum 16-way DI, PNP type, maximum 8-way DO, NPN/PNP configurable (the same interface DI, DO, IO-Link protocol cannot be reused), 24VDC power supply, automatic negotiation mechanism, automatic flip function, metal shell.


IACM-IOLM8B-ECT-E

IACM-IOLM8B-ECT-E coupler is a field-type IO-Link master module, EtherCAT bus protocol, 8-way IO-Link interface, 8-way ClassB; maximum 8-way DI, PNP type, maximum 8-way DO, NPN/PNP configurable (the same interface DI, DO, IO-Link protocol cannot be reused), 24VDC power supply automatic negotiation mechanism, automatic flip function, metal shell.

Payment & Shipping Terms


Minimum Order Quantityone
Delivery Time5 work days
StockIn Stock
Description8-port series, IOLINK master station
Payment TermsT/T, Western Union
Supply Ability1000 per day


Product Parameter

Model

IACM-IOLM8A-ECT-E

IACM-IOLM8B-ECT-E

Description

8* Class A,EtherCAT interface IO-Link master

8* Class B,EtherCAT interface  IO-Link master

Bus transfer

Communication protocol

EtherCAT

Working type

Automatic negotiation mechanism, automatic flip function

Transmission rate

10/100 Mbps

Address allocation

Profinet std.,DCP

Topology function

Support

Ring redundancy function (MRP)

Support

Power supply

Working voltage

24 VDC(18~30VDC)

Module current consumption

Max.200mA

System and input signal power supply

US,less than 8A

Auxiliary power supply

UA,less than 8A

Electrical isolation

US/UA:24Vseclusion,0Vseclusion

Interface

Power

2 * L-code 5pin,Pin end (input) + hole end (output)

Bus communication

2 * M12 D-code 4pin,Hole end

Signal connection

8 * M12 A-code 5pin,hole end

Electrical

Interface signal type

DI/DO/IO-Link Software configurable

IO-Link channel number

8

IO-Link interface type

ClassA/ Class-B for option

8*ClassB

IO-Link version

IO-Link V1.1

IO-Link transmission rate

COM1(4.8kbps)、COM2(38.4kbps)、COM3(230.4kbps)

Input channel number

Max 16

Max 8

Output supply current (Pin1 & Pin3)

IO-Link Interface max. 1.6A, common signal interface max.200mA

Auxiliary supply current (Pin2 & Pin5)

--

Max. per channel 2A

Input signal type

PNP

Output channel number

Max.8

Maximum load current Input/Output

Max. per channel 200mA

Output signal type

PNP or NPN(for option)

Output switching frequency

Resistive load 100Hz, inductive load 5Hz

Diagnosis

Communication status

LED Instructions, communication messages

Power supply monitoring

Yes, low voltage alarm

Short circuit and overload protection

Yes, LED indication

Protection level

IP67

Temperature range

Operating temperature -20~80°C (storage temperature -40~85°C)





FAQ

Q1: Does the IO-LINK master module require a dedicated gateway?

A: No additional gateway is required. The module directly integrates the EtherCAT/Profinet protocol and can be directly connected to the PLC master.


Q2: Can the 8 ports support devices with different protocols at the same time?

A: Yes. Each IO-LINK port works independently and can be mixed with sensors, actuators and other devices.


Q3: Is the protection level of the module suitable for oily environments?

A: IP67 protection design, resistant to oil, dust and water mist, but long-term immersion or high-pressure washing should be avoided.


Q4: Does it support third-party IO-LINK devices?

A: Fully compatible with IO-LINK V1.1 standard devices, including IFM, SICK and other brand sensors.


Q5: How to achieve multi-module cascade expansion?

A: Through the EtherCAT daisy chain topology, up to 32 modules can be cascaded and 256 IO-LINK nodes can be managed.


Previous: 
Next: 
Form Name

ABOUT US

Superisys (Wuhan) Intelligent Technology Co., Ltd., founded in 2018, is a professional manufacturer and service provider of industrial identification, industrial communication, industrial sensors and data solutions.

QUICK LINKS

CATEGORY

CONTACT US

  +86-13971499887 (Ms.Jayne Yang)
 +8613971499887
 +86-13971499887
 12#-1B, Yangluo Liandong U Valley Elctronic Tech Industrial Park, #36 Jinfa Avenue, Intelligent Manufacture Industrial Park, Changjiang New District, Wuhan, Hubei, China.
contact WhatsApp
contact1 WeChat
​Copyright © 2025 Superisys (Wuhan) Intelligent Technology Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy