RF-HZMTC4022M-112/2K
Superisys
Availability: | |
---|---|
Quantity: | |
Working frequency: 13.56MHz (compliant with ISO/IEC 15693 standard)
Reading distance: Stable reading distance on metal surface 5-20cm (depending on reader power)
Anti-interference: Adopting special electromagnetic isolation layer design, the reading stability in metal environment is improved by more than 60%
Multi-tag recognition: Supports high-speed anti-collision algorithm and can recognize 50+ tags at the same time
Protection level: IP67 (dustproof and waterproof)
Resistant to common industrial liquids such as engine oil and cutting fluid
Resistant to weak acid and weak alkali (pH3-10)
Service life: >100,000 read and write cycles in industrial environmen
product model | RF-HZMTC4022-112 | RF-HZMTC4022-2K |
working frequency | 13.56MHz | |
Air port agreement | ISO 15693 | |
Read distance | 0-80mm(Related to read head) | |
User memory | 112 Bytes | 2000 Bytes |
Memory type | EEPROM | FRAM |
Rewrite cycle | 100,000 times | 10 Billion times |
Data storage time | 10 years | 10 years |
size | φ40*22*4.8mm | |
Housing material | PPS | |
Fixed mode | Scewing | |
IP rating | IP68 | |
Operating temperature | -40~70℃ | |
Storage temperature | -40~+105℃ | |
Metal resistance | Non-Antimetal metal |
Working frequency: 13.56MHz (compliant with ISO/IEC 15693 standard)
Reading distance: Stable reading distance on metal surface 5-20cm (depending on reader power)
Anti-interference: Adopting special electromagnetic isolation layer design, the reading stability in metal environment is improved by more than 60%
Multi-tag recognition: Supports high-speed anti-collision algorithm and can recognize 50+ tags at the same time
Protection level: IP67 (dustproof and waterproof)
Resistant to common industrial liquids such as engine oil and cutting fluid
Resistant to weak acid and weak alkali (pH3-10)
Service life: >100,000 read and write cycles in industrial environmen
product model | RF-HZMTC4022-112 | RF-HZMTC4022-2K |
working frequency | 13.56MHz | |
Air port agreement | ISO 15693 | |
Read distance | 0-80mm(Related to read head) | |
User memory | 112 Bytes | 2000 Bytes |
Memory type | EEPROM | FRAM |
Rewrite cycle | 100,000 times | 10 Billion times |
Data storage time | 10 years | 10 years |
size | φ40*22*4.8mm | |
Housing material | PPS | |
Fixed mode | Scewing | |
IP rating | IP68 | |
Operating temperature | -40~70℃ | |
Storage temperature | -40~+105℃ | |
Metal resistance | Non-Antimetal metal |
1. Intelligent manufacturing field
Precision tool management: Installed on the tool handle of CNC machine tools, resistant to coolant environment, tool life tracking and automatic identification of tool change
Automated production line: automotive welding fixture identification, electronic assembly fixture management
2.Medical equipment management
Surgical instrument tracking: resistant to high temperature and high pressure sterilization (121℃ short term), precise management of individual instruments
Medical equipment maintenance: equipment shell installation, recording maintenance cycle and usage data
1. Intelligent manufacturing field
Precision tool management: Installed on the tool handle of CNC machine tools, resistant to coolant environment, tool life tracking and automatic identification of tool change
Automated production line: automotive welding fixture identification, electronic assembly fixture management
2.Medical equipment management
Surgical instrument tracking: resistant to high temperature and high pressure sterilization (121℃ short term), precise management of individual instruments
Medical equipment maintenance: equipment shell installation, recording maintenance cycle and usage data
FAQ
Q1: Does the HF RFID Tag require an external antenna on the metal surface?
A: No external antenna is required. HZMTC4022 can be directly attached to the metal surface for use.
Q2: How is the high temperature resistance of the tag?
A: The operating temperature range is -40℃~150℃, suitable for high-temperature sterilization (such as medical equipment) or low-temperature storage scenarios.
Q3: Does it support batch encoding?
A: Yes. UID or user data can be quickly written in batches through the reader/writer to improve deployment efficiency.
Q4: How long is the life of the tag?
A: Passive design, theoretical life of more than 10 years, read and write times ≥100,000 times, no daily maintenance requirements.
Q5: How to ensure data security?
A: Supports password protection and data encryption to prevent unauthorized tampering or cloning.
FAQ
Q1: Does the HF RFID Tag require an external antenna on the metal surface?
A: No external antenna is required. HZMTC4022 can be directly attached to the metal surface for use.
Q2: How is the high temperature resistance of the tag?
A: The operating temperature range is -40℃~150℃, suitable for high-temperature sterilization (such as medical equipment) or low-temperature storage scenarios.
Q3: Does it support batch encoding?
A: Yes. UID or user data can be quickly written in batches through the reader/writer to improve deployment efficiency.
Q4: How long is the life of the tag?
A: Passive design, theoretical life of more than 10 years, read and write times ≥100,000 times, no daily maintenance requirements.
Q5: How to ensure data security?
A: Supports password protection and data encryption to prevent unauthorized tampering or cloning.